01 — EMC Fundamentals

EMC Fundamentals

Electromagnetic Compatibility (EMC) requires that a device (1) does not emit interference that disrupts other equipment, and (2) is immune to interference from its environment. Every EMC problem has three elements — a source, a coupling path, and a receptor. Eliminate any one and the problem disappears.

EMC Interference Budget
Margin = Immunityreceptor(dBμV/m) − Emissionsource(dBμV/m) − Coupling(dB) > 0
E-field (dBμV/m) = 20·log₁₀(E in μV/m) · E = V/m = √(P·Rrad·30)/d
0 dBμV = 1 μV referenced · 0 dBμV/m = 1 μV/m field strength
Typical ambient noise floor: −10 to +20 dBμV/m (urban, 1–1000 MHz)

The Four Coupling Paths

Coupling ModeMechanismFrequency RangePrimary Fix
ConductiveDirect wire/trace connection — shared impedance, ground loopsDC–100 MHzFiltering, star ground, isolation
CapacitiveElectric field coupling between adjacent traces/components1 MHz–1 GHzPhysical separation, guard traces, shielding
InductiveMagnetic field coupling between loops (mutual inductance)100 kHz–100 MHzReduce loop area, 90° orientation, shielding
RadiativeFar-field electromagnetic wave coupling>30 MHzShielding, antenna separation, filtering
The source/path/receptor framework: A 100 MHz clock radiating from a PCB trace (source) → coupling through air (path) → desensing a 100 MHz IF filter in an adjacent receiver (receptor). Fix at the cheapest point: add a ferrite bead on the clock line (source), add PCB shielding can (path), or add a bandpass filter at the IF input (receptor). In practice: fix all three.
02 — Emissions

Conducted & Radiated Emissions

Conducted Emissions (CE)

Conducted emissions are RF noise currents that flow on the power supply lines and I/O cables. They are measured using a Line Impedance Stabilisation Network (LISN) — a standardised 50 Ω impedance presented to the EUT across 150 kHz–30 MHz.

Conducted Emission Limits — FCC Part 15B Class B (Residential)
150 kHz – 500 kHz: 66 dBμV quasi-peak, 56 dBμV average
500 kHz – 5 MHz: 56 dBμV quasi-peak, 46 dBμV average
5 MHz – 30 MHz: 60 dBμV quasi-peak, 50 dBμV average
Class A (commercial): limits are 10 dB higher — easier to meet
CISPR 32 Class B: similar limits, European standard (CE marking)
CE SourceMechanismFrequencyFix
SMPS switchingDrain/inductor node voltage swingsfsw harmonics: 100 kHz–10 MHzCM choke + X/Y caps on AC input
Clock harmonicsCurrent spikes on Vdd at clock edgeFundamental + odd harmonicsSpread-spectrum clocking, decoupling
I/O cableCM current on cables acting as antennas30–300 MHzCM filter at cable entry, cable ferrite
MicroprocessorDynamic power supply current spikesBroadbandBulk + HF decoupling capacitors

Radiated Emissions (RE)

Radiated Emission Limits — FCC Part 15B (measured at 3 m / 10 m)
30–88 MHz: Class B 100 μV/m = 40 dBμV/m at 3 m
88–216 MHz: Class B 150 μV/m = 43.5 dBμV/m at 3 m
216–960 MHz: Class B 200 μV/m = 46 dBμV/m at 3 m
>960 MHz: Class B 500 μV/m = 54 dBμV/m at 3 m
Class A at 10 m: same field strength → effectively 20 dB more relaxed than Class B at 3 m
Example 1 — Estimating radiated emission from a PCB trace
100 MHz clock, 20 mA current loop, loop area A=1 cm² = 1×10⁻⁴ m², measured at d=3 m

1
Electric field from small loop: E = (2π·f)²·μ₀·I·A·sinθ / (4π·c·d) = (2π×10⁸)²×4π×10⁻⁷×0.02×10⁻⁴/(4π×3×10⁸×3)
2
E = (3.948×10¹⁷)×(8π×10⁻⁷)×(2×10⁻⁶)/(1.131×10¹⁰) = 1.75×10⁻⁴ V/m = 175 μV/m
3
In dBμV/m: 20·log₁₀(175) = 44.9 dBμV/m
4
FCC Class B limit at 88–216 MHz: 43.5 dBμV/m → we EXCEED by 1.4 dB — FAIL!
5
Fix: reduce loop area from 1 cm² to 0.5 cm² (route return path adjacent) → E drops 6 dB → 38.9 dBμV/m — PASS with 4.6 dB margin
✓ Loop area reduction is the single most effective fix. Halving loop area = 6 dB reduction. Quarter area = 12 dB. Return current routing is the EMC engineer's most powerful tool.
03 — Immunity & ESD

Immunity & ESD

Immunity testing verifies that the product survives being exposed to externally generated interference. Key tests include ESD (electrostatic discharge), EFT (electrical fast transient), surge, conducted RF immunity, and radiated RF immunity.

TestStandardLevel (Class 3/4)WaveformPCB Mitigation
ESD ContactIEC 61000-4-2±4 kV / ±8 kV0.7 ns rise, 60 ns halfTVS diodes, GDTs, chassis ground
ESD AirIEC 61000-4-2±8 kV / ±15 kV0.8 ns riseCreepage, conformal coating
EFT/BurstIEC 61000-4-4±2 kV / ±4 kV5 ns rise, 50 ns width, 5 kHz burstCM choke, Y-caps on I/O
SurgeIEC 61000-4-5±2 kV / ±4 kV1.2/50 μsMOV, TVS, gas discharge tube
Conducted RFIEC 61000-4-63 V / 10 V EMF0.15–80 MHz CW/AMCM filters, decoupling, shielding
Radiated RFIEC 61000-4-33 V/m / 10 V/m80–1000 MHzShielding, filtering, layout
ESD the most common failure mode: A human body model (HBM) ESD event discharges 100 pF at 1500 Ω → ~100 mJ in 150 ns. This can destroy gate oxides (MOS), punch through junctions, or corrupt memory. TVS diodes clamp to 5–15 V within <1 ps. Place them on every external connector pin, as close to the connector as possible — before any ESD-sensitive component.
04 — Shielding

Shielding Effectiveness

Shielding attenuates electromagnetic fields by reflection (wave impedance mismatch at the conductor surface) and absorption (energy dissipated by induced currents in the conductor). Total shielding effectiveness SE = A + R + B (absorption + reflection + multiple reflection correction).

Shielding Effectiveness
A = 131.4·t·√(f·μr·σr)   (absorption loss in dB, t in metres)
R = 168 − 10·log₁₀(f·μrr)   (reflection loss — plane wave, dB, σr relative to copper)
SE = A + R + B   (B ≈ 0 for A > 15 dB)
Skin depth δ = 1/√(π·f·μ·σ) mm · Copper: δ = 66.5/√f[Hz] μm · Steel: δ = 16.7/√f[Hz] μm (μr=100)

Shielding Effectiveness Examples

Example 2 — SE for 1 mm copper and 1 mm steel at 100 MHz
1
Copper δ at 100 MHz = 66.5/√(10⁸) = 6.65 μm · 1 mm = 150 skin depths → A = 131.4×0.001×√(10⁸×1×1) = 131.4 dB
2
Copper R at 100 MHz: 168−10·log₁₀(10⁸×1/1) = 168−80 = 88 dB
3
Copper SE ≈ 131.4+88 = 219 dB — solid copper is impractical to analyse — all SE is limited by apertures!
4
Steel SE at 100 MHz: A=131.4×0.001×√(10⁸×100×0.1) = 131.4×√(10⁹) = 415 dB (higher μ, lower σ)
5
Aperture-limited SE: SEaperture = 20·log₁₀(λ/2L) for aperture of max dimension L
6
10×10 mm ventilation hole at 100 MHz: λ=3 m, SE = 20·log₁₀(3/(2×0.01)) = 43.5 dB — aperture limits the whole shield!
✓ The metal wall is essentially transparent. Every aperture (seam, vent, display, connector cutout) limits SE. At 1 GHz, the same hole gives only 23.5 dB. Cover vents with wire mesh (aperture = mesh cell, not vent hole).
Seams are the weakest point: A 10 mm gap in a 1 GHz enclosure has the same SE as a 10 mm aperture — 23.5 dB. EMC gaskets (conductive foam, spring fingers, copper tape) are essential. A single seam can reduce a 100 dB shield to 20 dB. Check every seam, hinge, and removable panel with a field probe before your EMC pre-scan.
05 — EMI Filtering

EMI Filtering

EMI filters attenuate noise on power lines and I/O cables. The key distinction is between differential mode (DM) noise — current that flows line-to-line — and common mode (CM) noise — current that flows line-to-ground (or ground plane) on all conductors simultaneously.

Differential vs Common Mode
DM noise: IL = −IN (opposite on line and neutral) · Filter: X-capacitor + DM inductor
CM noise: IL = IN (same direction on both) · Filter: Y-capacitors + CM choke
Insertion loss (IL) = 20·log₁₀(Vsource/Vload) with filter in circuit dB
Typically need IL > 30–50 dB at the offending frequency to pass FCC/CISPR

Common Mode Choke Design

Example 3 — CM choke for 1 MHz SMPS conducted emission fix
1
Measured CE at 1 MHz = 72 dBμV · FCC Class B limit = 56 dBμV · Need IL = 16 dB minimum, target 26 dB (10 dB margin)
2
Select Würth 744235601 CM choke: LCM=6 mH, DCR=0.36 Ω, Irated=1A
3
IL ≈ 20·log₁₀(1 + ZCM/Zsource) at 1 MHz: ZCM=2πfL=37.7 kΩ vs Zsource=50 Ω (LISN) → IL = 20·log₁₀(755) = 57.6 dB
4
Add Y-caps: 4.7 nF line-to-ground each side · ZY at 1 MHz = 1/(2π×10⁶×4.7×10⁻⁹) = 33.9 Ω
5
Combined LC filter IL increases further — predict 60+ dB, test confirms 65 dBμV → 7 dBμV = 49 dB reduction
✓ CM choke + Y-caps gives 49 dB attenuation. Final CE = 72−49 = 23 dBμV — 33 dB below FCC Class B limit of 56 dBμV. Note: Y-cap is safety-limited to 4.7 nF for 50/60 Hz leakage current compliance.
06 — Grounding & Ground Planes

Grounding & Ground Planes

The ground plane is not just a 0 V reference — it is the return current path for every signal on the PCB. Signal current flows on the trace; return current flows on the ground plane directly beneath the trace (image plane effect). Interrupting the return current path forces it to detour, creating large loop areas and emissions.

Grounding RuleWhyConsequence if Broken
Solid ground plane, no splitsReturn current follows signal trace aboveSplit → return current detours → large loop area → radiation
No via stitching under tracesVias interrupt return current on planeGround plane becomes a slot antenna
Star ground for analogPrevents ground loops at LFShared impedance → hum, 50/60 Hz interference
Single-point chassis bond at PCBPrevents CM ground loop via chassisGround loop → radiated emission antenna
Decoupling caps at every IC Vdd pinReduces Vdd spike amplitude and loop areaLarge current spikes → radiated emission from IC loop
Guard ring around sensitive analogReturns stray capacitive currents locallyCapacitive crosstalk from digital into analog
The 20H rule: Extend the power plane 20× the dielectric thickness inside the ground plane edges. A 1.6 mm dielectric → 32 mm power plane setback. Reduces edge-radiated fields from the power/ground plane parallel plate cavity by ~70% at frequencies where the cavity resonates. Widely used in high-speed digital PCB design.
07 — PCB EMC Design

PCB EMC Design Rules

AreaRuleReason
StackupSignal / Ground / Power / Signal (4-layer minimum for EMC)Every signal has a reference plane return path within 0.1 mm
ClocksRoute away from board edges and I/O connectors. Terminate with series resistor (22–33 Ω)Board edges radiate. Series termination reduces overshoot → harmonics
Decoupling100 nF ceramic 0402 within 2 mm of each IC Vdd pin. 10 μF bulk per power railHF decoupling reduces di/dt voltage spike on Vdd
SMPS layoutMinimise hot loop area (switch node → inductor → output cap → return)Hot loop radiates proportional to I×A×f²
I/O filteringFilter all I/O at board edge — before connector pinCables act as antennas — filter at board edge before cable picks up
Crystal/oscillatorPlace close to IC, guard ring, no signals crossing belowCrystal is a broadband noise source — minimise coupling length
RF sectionShield can around RF front end, solid ground plane, RF traces <λ/20RF signals radiate at any length >λ/20 — λ/20 at 2.4 GHz = 6.25 mm
Via stitchingRow of ground vias every λ/20 along RF traces and at shield can perimeterGround return path must be <λ/20 or plane becomes antenna
08 — Regulatory Standards

Regulatory Standards

StandardRegionCoversClassProduct Type
FCC Part 15BUSAUnintentional radiatorsA (commercial), B (residential)PCs, TVs, embedded, IoT
CISPR 32EU/GlobalMultimedia equipment emissionsA, BAudio/video, IT equipment
CISPR 25GlobalAutomotive emissionsClasses 1–5Vehicle electronics, EV
IEC 61000-4-xEU/GlobalImmunity testingLevels 1–4Industrial, medical, consumer
RED 2014/53/EUEURadio equipment directiveAny product with radio
MIL-STD-461GUSA DoDMilitary EMCDefence electronics
DO-160GAvionicsEnvironmental + EMCAircraft equipment
FCC SDoC vs certification: Since 2017, most Class B devices use Supplier's Declaration of Conformity (SDoC) — self-declaration with test records held by manufacturer. Only intentional transmitters (WiFi, Bluetooth, cellular) still require FCC lab certification (ID) through an accredited test lab. SDoC does not mean no testing — you still need ANSI C63.4 measurements, just without FCC submission.
CE marking for EU market: CE marking requires a Declaration of Conformity against all applicable directives — typically LVD (low voltage), RED (radio), and RoHS. The test lab must be accredited to ISO/IEC 17025. Using a CISPR 32 compliant report as the basis for CE is the most common path for consumer electronics.
09 — EMC Debug

EMC Debug Techniques

TechniqueEquipmentBest For
Near-field scanningLoop/E-field probe + spectrum analyserFinding which trace/IC radiates most — mm spatial resolution
Conducted pre-scanLISN + spectrum analyserCE before formal test — identify offending frequencies
Radiated pre-scanBiconical/log-periodic antenna + SARE estimate in shielded room or open area — within 6 dB of formal test
Current probeRF clip-on CM current probeIdentifying which cable carries the most CM current
Ferrite bead testSnap-on ferrite + SARapid CE fix — confirms ferrite will work before soldering
Copper tape seal testConductive copper tape + SAConfirm seam is the culprit — tape seals the seam temporarily
Time domain (TDEMI)Wideband ADC receiverCaptures emissions vs time — identifies burst sources (SMPS, WiFi)
The $50 fix principle: The earlier in the design cycle you address EMC, the cheaper the fix. PCB layout change at schematic review: $50. Spin a new board: $2,000. Add a shielding can after board failure: $5,000. Fail at certification, redesign, re-test: $50,000+. EMC pre-scan your own design at every board revision — before formal test lab booking.

Electromagnetic Compatibility in RF Design

EMC (electromagnetic compatibility) ensures that a device neither generates more interference than permitted (emissions) nor is disrupted by the interference present in its environment (immunity). For RF products, EMC is not optional — it is a legal requirement for market access in every major region: FCC Part 15/18 in the USA, CE marking under the Radio Equipment Directive in the EU, MIC in Japan, and BIS in India. Products that fail pre-compliance EMC testing face costly redesign cycles late in development.

Conducted vs Radiated Emissions

Conducted emissions travel through power supply lines and signal cables. Radiated emissions propagate through space as electromagnetic waves. Both are measured in dBμV/m (radiated) or dBμV (conducted) against strict regulatory limits. Above approximately 30 MHz, radiated emissions dominate. Below 30 MHz, conducted emissions are the primary concern. RF circuits operating at 2.4 GHz or above always need radiated emissions testing from the fundamental frequency and its harmonics down to at least 1 GHz below the operating band.

Common RF EMC Design Rules

Key practices to reduce RF emissions: keep high-frequency digital clocks away from antenna traces; use a continuous ground plane under RF traces with no breaks or slots; route RF signals over a reference plane on an adjacent layer; decouple every power pin within 0.5 mm with a 100 nF ceramic capacitor; use common-mode chokes on external cables; keep crystal oscillator traces as short as possible and surround with a guard ring connected to ground at multiple vias. A 6 dB reduction in conducted noise on the power rail typically produces a 6 dB reduction in radiated emissions at the fundamental.